WILO Stratos MAXO 30/0,5-6 PN10 180mm

Smart glandless circulator with screwed connection or flange connection, EC motor with integrated electronic power adjustment See more

Technical Specifications

Maximum head [m]
10
Input voltage [V]
230
Power output - P2 [kW]
0.11
Suction port ["]
2

Show all Tech Specs

716.65 VAT included

the price includes a recycling fee

Delivery accross EU within 2-4 days %

Brand:
WILO
Category:
Circulator pumps
Product No.:
ZB00052043
Sale group:
CEW17
EAN:
4048482699424
Manuf. No.:
2164573

Product variants

  • Technical Specifications
  • Product No.
  • Maximum flow [l/min]
  • Maximum head [m]
  • Input voltage [V]
  • Power output - P2 [kW]
  • Suction port ["]
  • Delivery port ["]
  • Maximum current [A]
  • Protection [IP]
  • Dry run protection
  • Off switch
  • Speed ​​control
  • Capacitor
  • Impeller material
  • Port-to-port length
  • Availability
  • Price

next

Variant Product No.

Availability

Price (VAT incl.)

You are viewing this variant

WILO Stratos MAXO 32/0,5-8 PN6/10 220mm

Product No.: ZB00052048 Sale group: CEW17 EAN: 4048482699547 Manuf. No.: 2164578

808.15 €

Maximum flow [l/min]
166
Maximum head [m]
8
Input voltage [V]
230
Power output - P2 [kW]
0.16
Suction port ["]
DN32
Delivery port ["]
DN32
Maximum current [A]
1.10
Protection [IP]
X4D
Dry run protection
YES
Off switch
YES
Speed ​​control
YES
Capacitor
integrated
Impeller material
noryl
Port-to-port length
220

Product description

Your advantages

  • Various options for integration into building management systems

  • Intuitive operation by means of application-guided settings with the Setup Guide plus the combination of a new display and operating button using Green Button Technology.

  • Maximum energy efficiency thanks to the combination of optimised and innovative energy-saving functions (e.g. No-Flow Stop).

  • Optimum system efficiency thanks to new and innovative intelligent control functions, such as Dynamic Adapt plus, Multi-Flow Adaptation, T-const. and ΔT-const.

  • Latest communication interfaces (e.g. Bluetooth) for connection to mobile devices and direct pump networking for multiple pump control via Wilo Net.

  • Maximum convenience in electrical installation thanks to a clearly arranged and spacious terminal room and the optimised Wilo-Connector.

The smart-pump for commercial buildings with building management system.

With optimised and innovative energy-saving features, the Wilo-Stratos MAXO sets new standards for commercial HVAC and drinking water applications in terms of energy efficiency. Its outstanding user-friendliness makes operating the pump easier than ever before.

Construction

Smart glandless circulator with screwed connection or flange connection, EC motor with integrated electronic power adjustment.

Application

Hot-water heating systems of all kinds, air-conditioning systems, closed cooling circuits, industrial circulation systems.

Equipment/function

Field of application

The pump facilitates an operation with highest system efficiency via precise setting of the control mode for the system-specific application (e.g. radiator, underfloor heating, ceiling cooling).

Heating

  • Radiator

  • Underfloor heating

  • Ceiling heating

  • Fan heater

  • Hydraulic shunt

  • Heat exchanger

Cooling

  • Ceiling cooling

  • Underfloor cooling

  • Air-conditioning devices

  • Hydraulic shunt

  • Heat exchanger

Heating and cooling combined

  • Automatic switchover

The following control modes are available depending on the selected application:

Control modes

  • Constant speed (control mode)

  • Δp-c for constant differential pressure

  • Δp-v for variable differential pressure

  • Dynamic Adapt plus for continuous (dynamic) adjustment of the delivery rate to the current requirement

  • T-const. for constant temperature regulation

  • ΔT for differential temperature control

  • Constant Q for constant volume flow control

  • Multi-Flow Adaptation: Total volume flow determination through the feeder pump for the needs-based supply of secondary pumps in the heating circuit distributors

  • User-defined PID controller

Optional functions

  • Q-limitmax. for limiting the maximum volume flow

  • Q-limitmin. for limiting the minimum volume flow

  • No-Flow Stop (zero-flow-deactivation)

  • Automatic setback operation

  • Index circuit evaluator (Δp-c control with external actual value sensor)

  • Variable pitch of Δp-v pump curve

Manual settings

  • Selection of the field of application using the Setup Guide

  • Setting the related operating parameters

  • Nominal duty point: direct input of calculated duty point at Δp-v

  • Status display

  • Setting and resetting the energy meters (heating and cooling)

  • Pump venting function

  • Key lock for disabling the settings

  • Function for resetting the factory settings or the saved restoration points (parameter sets)

  • Parameterising the analogue inputs

  • Parameterising the binary inputs

  • Parameterising the relay outputs

  • Dual pump function (for 2 single pumps, which should be operated as twin-head pump)

Automatic functions

  • Power adjustment according to requirements for energy-efficient operation depending on the operating mode

  • Setback operation

  • Deactivation at zero flow (No-Flow Stop)

  • Soft start

  • Automatic troubleshooting routines (e.g. deblocking function)

  • Switchover heating/cooling mode

  • Full motor protection with integrated trip electronics

External control inputs and their functions

  • 2 x analogue inputs:

  • Signal types: 0 – 10 V, 2 – 10 V, 0 – 20 mA, 4 – 20 mA, PT1000

  • Applications: Remote adjustment of the setpoints in every control mode (except Multi-Flow Adaptation), sensor inputs for temperature, differential pressure or free sensor in user-defined PID-operating mode

  • 2 x digital inputs:

  • For potential-free control outputs or switch

  • Parametrizable functions:

    • Ext. Off

    • Ext. Min

    • Ext. Max

    • MANUAL (BMS-OFF)

    • Key lock

    • Switchover between heating/cooling mode

Wilo Net for dual pump management of 2 single pumps, communication of several pumps with each other and pump-remote adjustment via gateway

Signal and display functions

  • Display status operation display:

    • Setpoint

    • Actual delivery head

    • Actual volume flow

    • Power consumption

    • Electric consumption

    • Temperatures

  • Status display LED: Faultless operation (green LED), pump communication (blue LED)

  • Display status of display fault (display red):

    • Error codes and error description in full text

    • Remedial measures

  • Display status of display warning (display yellow):

    • Warning codes and description of the warning in full text

    • Remedial measures

  • Display status process indicator (display blue):

    • Pump venting

    • Update procedure

  • Display BMS communication (display blue):

  • Summary of the active BMS parameters (baud rate, address,...)

  • Collective fault signal SSM (potential-free changeover contact)

  • Collective run signal SBM (potential-free normally open contact)

Data exchange

  • Bluetooth interface for wireless data exchange and remote operation of the pump using a smartphone or tablet.

  • Serial digital interface Modbus RTU for connecting building automation (BA) via RS485 bus system (possible with Wilo-CIF module Modbus RTU).

  • Serial digital interface BACnet MS/TP for connecting building automation (BA) via RS485 bus system (possible with Wilo-CIF module BACnet MS/TP).

  • Serial digital interface LON for connecting building automation (BA) via bus system LONWorks (possible with Wilo-CIF module LON).

  • Serial digital interface PLR for connecting BA via company-specific coupling module (possible with Wilo-CIF module PLR).

Dual pump management (twin-head pump or 2 x single pumps)

  • Main/standby operation (automatic fault-actuated switchover/time-sensitive pump alteration)

  • Parallel operation (efficiency-optimised peak load cut-in and out)

Equipment

  • For flange-end pumps: Flange versions

    • Standard version for DN 32 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges

    • Standard version for DN 80/DN 100 pumps: PN 6 flange (designed for PN 16 according to EN 1092-2) for PN 6 counter flange

    • Special version for DN 32 to DN 100 pumps: PN 16 flange (according to EN 1092-2) for PN 16 counter flange

  • Various integrated communication interfaces and optionally usable CIF module plug-in position

  • 5 cable inlets for connecting the communication interfaces

  • Bluetooth interface

  • High resolution graphic display with green button and 2 additional buttons

  • User-friendly terminal room

  • Integrated temperature sensor

  • Thermal insulation as standard for heating applications

  • Quick electrical connection with optimised Wilo-Connector for the power supply

Scope of delivery

  • Pump

  • Optimised Wilo-Connector

  • 2x threaded cable connection M16 x 1.5

  • Washers for flange screws (for nominal connection diameters DN 32 - DN 65)

  • Gaskets for threaded connection

  • Thermal insulation

  • Installation and operating instructions

Type key

Example:

Wilo-Stratos MAXO 30/0,5-12

Stratos MAXO

High-efficiency pump (screw-end or flange-end pump), electronically controlled

30/

Nominal connection diameter

0,5-12

Nominal delivery head range [m]

Materials

  • Pump housing: grey cast iron with cataphoretic-coated

  • Thermal insulation: polypropylene

  • Shaft: Stainless steel

  • Bearing: carbon

  • Impeller: Plastic

 

Description/construction

  • Smart glandless circulator with EC motor and integrated electronic power adjustment

  • Green Button Technology and graphic display

  • Motor protection with trip electronics

  • Plug connection for functional extension with optional CIF module for building automation (BA)

  • Impeller with three-dimensionally curved blades and plastic sealing tube made of carbon fibre composite material

 

Technical Specifications

Maximum head [m]
10
Input voltage [V]
230
Power output - P2 [kW]
0.11
Suction port ["]
2
Delivery port ["]
2
Maximum current [A]
0.90
Impeller material
noryl