WILO Stratos 30/1-6 180mm 230V PN10

Glandless circulator with threaded connection or flange connection, EC motor with automatic power adjustment See more

537.76 VAT included

the price includes a recycling fee

Delivery accross EU within 2-4 days %

Brand:
WILO
Category:
Circulator pumps
Product No.:
ZB00004011
Sale group:
CEW02
Manuf. No.:
2090449

Product description

Your advantages

  • Energy savings due to greater system efficiency with the Q-Limit function (volume flow limiter)

  • Improved Energy Efficiency Index (EEI) ≤ 0.20 for all single pumps

  • Enhanced display for better readability and ease of operation

  • Space-saving installation thanks to compact design and variable-orientation LC display

  • Modular concept for connection of all conventional bus systems (e.g. Modbus, BACnet, CAN, LON and PLR)

  • Tried-and-tested quality and reliability

Phasing out program

After 19 successful years, the Wilo-Stratos high-efficiency pump will be removed from our product range at the end of the year. It will be fully superseded by the new Wilo-Stratos MAXO smart pump. The successful era of the Stratos series will continue with the Stratos MAXO’s new pump technology.

Construction

Glandless circulator with threaded connection or flange connection, EC motor with automatic power adjustment.

Application

Hot-water heating systems of all kinds, air-conditioning systems, closed cooling circuits, industrial circulation systems.

Equipment/function

Operating modes

  • Constant speed (n=constant)

  • Δp-c for constant differential pressure

  • Δp-v for variable differential pressure

  • Δp-T for temperature-controlled differential pressure (programmable via IR-Stick, IR-Monitor, Modbus, BACnet, LON or CAN)

  • Q limit for limiting the maximum volume flow (setting only via IR-stick)

Manual functions

  • Setting the operating mode

  • Differential pressure setpoint setting

  • Setting automatic setback operation

  • Setting the pump ON/OFF

  • Setting the speed (manual control mode)

Automatic functions

  • Continuous power adjustment according to the operating mode

  • Automatic setback operation

  • Deblocking function

  • Soft start

  • Full motor protection with integrated trip electronics

External control functions

  • "Overriding Off" control input (possible with Stratos IF-Modules)

  • "Overriding Min" control input (possible with Stratos IF-Modules)

  • "Analogue In 0 - 10 V" control input (remote speed adjustment) (possible with Stratos IF-Modules)

  • "Analogue In 0 - 10 V" control input (remote setpoint adjustment) (possible with Stratos IF-Modules)

Signal and display functions

  • Collective fault signal (potential-free NC contact)

  • Individual run signal (potential-free NO contact) (possible with Stratos IF-Modules)

  • Fault signal light

  • LCD display for indication of pump data and error codes

Data exchange

  • Infrared interface for wireless data exchange with IR-Stick/IR-Monitor

  • Modbus RTU serial digital interface for connection to building automation BA via RS485 BUS system (possible with Stratos IF-Modules)

  • BACnet serial digital interface MS/TP Slave for connection to building automation BA via RS485 BUS system (possible with Stratos IF-Modules)

  • CAN serial digital interface for connection to building automation BA via CAN BUS system (possible with Stratos IF-Modules)

  • LON serial digital interface for connection to a LONWorks network (possible with Stratos IF-Modules)

  • PLR serial digital interface for connection to BA via Wilo interface converter or company-specific coupling modules (possible with Stratos IF-Modules)

Dual pump management (twin-head pump or 2 x single pumps)

  • Main/standby operation (automatic fault-actuated switchover/time-dependent pump cycling): various combinations with Stratos IF-Modules (accessories) possible

  • Parallel operation (efficiency-optimised peak load activation and deactivation): various combinations with Stratos IF-Modules (accessories) possible

Equipment

  • Wrench attachment point on pump body (for threaded pipe union pumps with P2 < 100 W)

  • For flange-end pumps: Flange versions

  • Standard version for DN 32 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges

  • Standard version for DN 80/DN 100 pumps: PN 6 flange (designed for PN 16 according to EN 1092-2) for PN 6 counter flange

  • Special version for DN 32 to DN 100 pumps: PN 16 flange (according to EN 1092-2) for PN 16 counter flange

  • Plug-in position for optional extension with Wilo-IF-Modules

  • Thermal insulation as standard for heating applications

Scope of delivery

  • Pump

  • Including thermal insulation

  • Including gaskets for threaded connection

  • Including washers for flange screws (for nominal connection diameters DN 32 - DN 65)

  • Including installation and operating instructions

Type key

Example:

Wilo-Stratos 30/1-12

Stratos

High-efficiency pump (screw-end or flange-end pump), electronically controlled

30/

Nominal connection diameter

1-12

Nominal delivery head range [m]

Materials

  • Pump housing: grey cast iron with cataphoretic coating

  • Thermal insulation: polypropylene

  • Shaft: Stainless steel

  • Bearing: carbon, metal impregnated

  • Impeller: Plastic

 

Description/construction

  • Glandless circulator with EC motor and integrated automatic power adjustment

  • Green Button Technology and graphic display

  • Motor protection with trip electronics

  • Plug connection for functional extension with optional IF module for building automation (BA)

  • Impeller with three-dimensionally curved blades and plastic sealing tube made of carbon fibre composite material